CONTROLE EXECUTIVO DE ESTACAS RAIZ A PARTIR DE MEDIDAS DE CAMPO

Autores/as

  • Diana Rodrigues de Lima Universidade Federal do Ceará, Centro de Tecnologia, Departamento de Engenharia Hidráulica e Ambiental, Campus do Pici, Avenida Mister Hull, Bairro Pici, Fortaleza, CE, Brasil
  • Alfran Sampaio Moura Universidade Federal do Ceará, Centro de Tecnologia, Departamento de Engenharia Hidráulica e Ambiental, Campus do Pici, Avenida Mister Hull, Bairro Pici, Fortaleza, CE, Brasil

Resumen

RESUMO Durante a execução das fundações de edificações, comumente se verifica a capacidade de carga por meio de métodos específicos que variam de acordo com o tipo de estaca. Para estacas raiz o controle é, em geral, feito por meio de ensaios de prova de carga. Este trabalho propõe uma formulação empírica para previsão carga de ruptura de estacas raiz, utilizando-se de algumas variáveis monitoradas durante a execução das mesmas utilizando um velocímetro digital. Para isso foram realizadas provas de carga estáticas lentas em três estacas raiz monitoradas, com diâmetros de 350 e 410 mm. Diversas combinações entre as parcelas da capacidade de carga de ponta e lateral e as variáveis monitoradas foram testadas, utilizando os programas de computador Excel e Maple. Posteriormente foi buscada uma equação para a previsão da carga de ruptura das estacas ensaiadas, como uma função das variáveis monitoradas, segundo relações do tipo polinomial, exponencial, logarítmica e combinação linear, tendo como referência o valor obtido no método da norma ABNT NBR 6122:2010. Foi verificado que há correlação entre a carga de ruptura e as variáveis monitoradas e os resultados obtidos pela equação proposta foram concordantes com os valores de referência para as estacas ensaiadas. Palavras-chave: estaca raiz; carga de ruptura; controle executivo. CONTROL OF ROOT PILES FROM FIELD MEASUREMENTS ABSTRACT During the execution of the foundations of buildings, the evaluation of the failure load is commonly determined by specific methods, which vary depending on the type of pile. The control of root piles are usually executed by load tests. This paper proposes an empirical formulation for prediction of failure load of root piles, using some variables that are monitored during the execution of the piles, using a digital speedometer. Therefore, slow static load test in three root piles monitored with diameters of 350 to 410 mm were conducted. Several combinations between portions of end bearing load capacity, side friction load capacity, and the monitored variables, were tested using computer programs as Excel and Maple. Afterwards, an equation for the prediction of the failure load of the piles tested was estimated, as a function of the monitored variables, according to polynomial relations, exponential, logarithmic and linear combination, referencing to the value obtained in Van der Veen's method (1953). It was found that there is a correlation between the failure load and the monitored variables, and the results obtained by the proposed equation were concordant with the reference values for the tested piles. Keywords: root pile; failure load; executive control.

Descargas

Los datos de descargas todavía no están disponibles.

Biografía del autor/a

Diana Rodrigues de Lima, Universidade Federal do Ceará, Centro de Tecnologia, Departamento de Engenharia Hidráulica e Ambiental, Campus do Pici, Avenida Mister Hull, Bairro Pici, Fortaleza, CE, Brasil

Mestre em Engenharia Civil, Geotecnia

Alfran Sampaio Moura, Universidade Federal do Ceará, Centro de Tecnologia, Departamento de Engenharia Hidráulica e Ambiental, Campus do Pici, Avenida Mister Hull, Bairro Pici, Fortaleza, CE, Brasil

Doutor em Geotecnia, Professor Adjunto, Eng. Civil, D.Sc., Programa de Pós-Graduação em Engenharia Civil, Departamento de Engenharia Hidráulica e Ambiental.

Publicado

2017-05-05

Número

Sección

Engenharia Civil