AVALIAÇÃO DE SISTEMA DE LEITO DE DRENAGEM NO DESAGUAMENTO DO LODO DE ESTAÇÃO DE TRATAMENTO DE ÁGUA COM ÊNFASE NA INFLUÊNCIA DOS AGENTES EXTERNOS NA FASE DE SECAGEM

Autores/as

  • Bruna Santos FECIV - UFU
  • André Luiz Oliveira FECIV - UFU
  • Márcio Ricardo Salla FECIV - UFU
  • José Eduardo Alamy Filho FECIV - UFU
  • Carlos Eugênio Pereira FECIV - UFU

DOI:

https://doi.org/10.14393/19834071.2014.24842

Resumen

Este trabalho teve como objetivo a avaliação do desempenho do sistema de Leito de Drenagem em escala reduzida no desaguamento de lodo de uma Estação de Tratamento de Ãgua. Foram avaliadas as fases de drenagem e secagem do lodo, sendo que na fase de secagem os ensaios foram conduzidos em duplicata para investigação da influência de fatores climáticos no tempo de secagem. Para tanto foram conduzidos experimentos com três Leitos de Drenagem, cada um com uma manta geotêxtil diferente, avaliados sob a aplicação de três distintas taxas de aplicação de sólidos. Uma vez escolhida a melhor taxa de aplicação de sólidos, foram conduzidos ensaios nos quais foi avaliada a influência parcial dos agentes externos apenas na fase de secagem, removendo-se a proteção lateral de um dos leitos. Foram avaliados, portanto, três mantas geotêxteis em ensaios em duplicata considerando a influência parcial ou não dos agentes climáticos. Assim, para cada manta estudada foram montados dois leitos de drenagem, um com a proteção lateral e outro sem a proteção lateral, totalizando seis leitos de drenagem. As fases de drenagem e de secagem do lodo foram avaliadas com taxas de aplicação de sólidos de 1,75 kg∙m-2, 3,5 kg∙m-2 e 7,0 kg∙m-2. Na fase de drenagem foi avaliado o parâmetro turbidez e na fase de secagem foi observada a influência das variáveis climáticas no desaguamento do lodo por meio da obtenção do teor de sólidos. Ressalta-se que os Leitos de Drenagem foram protegidos da incidência direta da chuva, ou seja, a influência foi indireta. O efluente do drenado apresentou, logo no início de operação do sistema, turbidez abaixo de 10 NTU e, ao final, próximo de 1 UNT e o lodo apresentou teor de sólidos 50% maior para o LD sem proteção lateral (envoltória). Palavras chaves: Estação de Tratamento de Ãgua (ETA), Geotêxteis, Lodo, Leitos de drenagem. ABSTRACT The aim of this work was to evaluate the performance of the System Draining Beds sludge dewatering in a Water Treatment Plant. Phase's drainage and drying of the sludge were evaluated, and the drying phase assays were conducted in duplicate for investigation of the influence of climatic factors on the drying time. Both experiments with three Draining Beds, each with a different geotextile, evaluated under the application of three different application rates of solids, were conducted. Once chosen the best application rate of solids, trials were conducted in which the partial influence of external agents was assessed only at the stage of drying, removing the lateral protection of the beds. Therefore, there were evaluated three geotextile blankets trials in duplicate considering partial or none influence of climatic agents. Then, for each bed studied, two blanket drain were assembled, one with side protection and other without side protection, totaling six beds of drainage. The steps of draining and drying of the sludge were evaluated at application rates of 1.75 kg∙m-2, 3.5 kg∙m-2 and 7.0 kg∙m-2 of solids. In a drain phase, the parameter turbidity was evaluated and in the drying step the influence of climate variables were observed in the dewatering of sludge to the obtained solids. It is noteworthy that the Draining Beds were protected from direct impact of rain, i.e., the influence was indirect. The effluent drained presented, earlier in the system operation, turbidity below 10 NTU and, at the end, turbidity near 1 NTU and the sludge solids showed 50% greater for the LD without lateral protection. Keywords: Water Treatment Plants (WTP), Geotextiles, Sludge, System Draining beds.

Descargas

Los datos de descargas todavía no están disponibles.

Biografía del autor/a

Bruna Santos, FECIV - UFU

Infraestrutura urbana - Faculdade de Engenharia Civil

André Luiz Oliveira, FECIV - UFU

Faculdade de Engenharia Civil - Hidráulica e Saneamento

Márcio Ricardo Salla, FECIV - UFU

Faculdade de Engenharia Civil - Hidráulica e Saneamento

José Eduardo Alamy Filho, FECIV - UFU

Faculdade de Engenharia Civil - Hidráulica e Saneamento

Carlos Eugênio Pereira, FECIV - UFU

Faculdade de Engenharia Civil - Hidráulica e Saneamento

Publicado

2014-10-23

Número

Sección

Engenharia Civil