AVALIAÇÃO DO DESEMPENHO DE UMA UNIDADE EM ESCALA REAL PARA TRATAMENTO DE ÁGUA PLUVIAL EMPREGANDO A FILTRAÇÃO DIRETA POR MEIO DE FILTRO DE PRESSÃO E AMIDO NATURAL DE MILHO COMO COAGULANTE PRIMÁRIO

Autores/as

  • Marcela Ferreira Murakami
  • Rodrigo Braga Moruzzi UNESP, Campus de Rio Claro

DOI:

https://doi.org/10.14393/19834071.2013.24025

Resumen

Este trabalho investigou o desempenho de um sistema experimental de tratamento de água pluvial, visando uso não potável. Optou-se por prescindir o descarte da primeira chuva (first flush) na expectativa de controlar a qualidade da água captada somente via sistema de tratamento e minimizar o volume descartado pelo first flush. Foram realizados ensaios de filtração direta em escala real com emprego de filtro de pressão e aplicação de solução de amido natural de milho como coagulante primário. Para avaliação do desempenho do sistema, foram analisadas a eficiência na remoção de impurezas ao longo das carreiras de filtração e a produção efetiva do sistema. Os resultados indicaram remoção de turbidez de até 70,8% e remoção de cor aparente de até 61,0%. A retrolavagem do sistema de filtração foi completada em 3 minutos a uma taxa de 1.440 m3/m2dia com consumo percentual de água tratada da ordem de 0,5 a 2,2% do volume potencialmente captável. Palavras-chave: água pluvial, captação, tratamento, aproveitamento, economia. PERFORMANCE ANALYSES OF A FULL-SCALE RAINWATER TREATMENT UNIT USING DIRECT FILTRATION AND STARCH AS PRIMARY COAGULANT ABSTRACT The aim of this study was to investigate the performance of an experimental rainwater treatment system for non-potable uses. Without the first-flush discharge it was expected to control the quality of captured rainwater and to minimize the rainwater by-pass caused by the first-flush strategy. A full-scale direct filtration unit was operated and a solution of natural corn starch was used as the primary coagulant. The color, turbidity e coliform efficiencies of the unit was analyzed based on filtration loads and the net water production was estimated. The results pointed out turbidity removal up to 70.8% and color removal up to 61.0%. The backwash of the filtering system was completed in 3 minutes at the rate of 1,440 m3/m2day with consumption of treated water from 0.5% to 2.2%, based on the potentially harvesting. Keywords: Rainwater, catchment, treatment, utilization, economy.

Descargas

Los datos de descargas todavía no están disponibles.

Biografía del autor/a

Marcela Ferreira Murakami

Engenheira Ambiental, Mestre em Engenharia Urbana pela Universidade Federal de São Carlos - UFSCar.

Rodrigo Braga Moruzzi, UNESP, Campus de Rio Claro

Engenheiro Civil, Mestre e Doutor em Engenharia Hidráulica e Saneamento pela Universidade de São Paulo (EESC/USP). Professor Assistente Doutor da Universidade Estadual Paulista

Publicado

2014-04-17

Número

Sección

Engenharia Civil